Description
CRP Series 500 – 2000
Must order a manifold if this is not an existing unit Find here
The Next Generation Molecular Filtration System
- Compression-fit manifold for precise filtration control
- Timer drain for improved flow of condensate through the media bed
- Antimicrobial sanitization of discharge hose to prevent algae growth
- Twelve available inlets (increased from six)
- No maintenance or messy bag change-outs
- Cradle-to-grave warranty
- System monitoring services
CRP 500
The CRP-500 is designed for systems from 30 HP to 250 HP.
CRP Unit | Width (in) | Depth (in) | Height (in) | Weight (lbs)* |
---|---|---|---|---|
500 | 16 | 15 | 48 | 110 |
*Height includes manifold. Height without manifold: 39 in
**shipping weight
HP | ACFM | Lifespan in Hours | Est. Hrs/Yr |
---|---|---|---|
30 | 150 | 32,000 | 8,000 |
40 | 200 | 24,000 | 8,000 |
50 | 250 | 19,000 | 8,000 |
60 | 300 | 16,000 | 8,000 |
75 | 375 | 13,000 | 8,000 |
100 | 500 | 11,000 | 8,000 |
125 | 600 | 8,000 | 8,000 |
150 | 750 | 6,000 | 8,000 |
200 | 1000 | 5,000 | 8,000 |
250 | 1250 | 4,000 | 8,000 |
Lifespan numbers in this chart assume screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Lifespans may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor.
RECIPROCATING COMPRESSORS (8 ppm carryover)
Unit Life: [cell from chart] x 0.25 x CF (see below)
Example: Micro 100 at 10 hp running 2,000 hrs/yr
Unit Life: 5,000 x 0.25 x 1 = 1,250 hours (or 7.5 months)
CRP 750
The CRP-750 is designed for systems from 40 HP to 300 HP.
CRP Unit | Width (in) | Depth (in) | Height (in) | Weight (lbs)* |
---|---|---|---|---|
750 | 16 | 15 | 48 | 125 |
*Height includes manifold. Height without manifold: 39 in
**shipping weight
HP | ACFM | Lifespan in Hours | Est. Hrs/Yr |
---|---|---|---|
40 | 200 | 32,000 | 8,000 |
50 | 250 | 25,000 | 8,000 |
60 | 300 | 21,000 | 8,000 |
75 | 375 | 17,000 | 8,000 |
100 | 500 | 13,000 | 8,000 |
125 | 600 | 11,000 | 8,000 |
150 | 750 | 8,000 | 8,000 |
200 | 1000 | 6,000 | 8,000 |
250 | 1250 | 5,000 | 8,000 |
300 | 1600 | 4,000 | 8,000 |
Lifespan numbers in this chart assume screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Lifespans may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor.
RECIPROCATING COMPRESSORS (8 ppm carryover)
Unit Life: [cell from chart] x 0.25 x CF (see below)
Example: Micro 100 at 10 hp running 2,000 hrs/yr
Unit Life: 5,000 x 0.25 x 1 = 1,250 hours (or 7.5 months)
CRP 1000
The CRP-1000 is designed for systems from 50 HP to 400 HP.
CRP Unit | Width (in) | Depth (in) | Height (in)* | Weight (lbs)** |
---|---|---|---|---|
1000 | 16 | 15 | 48 | 150 |
*Height includes manifold. Height without manifold: 39 in
**shipping weight
HP | ACFM | Lifespan in Hours | Est. Hrs/Yr |
---|---|---|---|
50 | 250 | 32,000 | 8,000 |
60 | 300 | 26,000 | 8,000 |
75 | 375 | 21,000 | 8,000 |
100 | 500 | 16,000 | 8,000 |
125 | 600 | 13,000 | 8,000 |
150 | 750 | 11,000 | 8,000 |
200 | 1000 | 8,000 | 8,000 |
250 | 1250 | 6,000 | 8,000 |
300 | 1600 | 5,000 | 8,000 |
350 | 1900 | 4,000 | 8,000 |
Lifespan numbers in this chart assume screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Lifespans may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor.
RECIPROCATING COMPRESSORS (8 ppm carryover)
Unit Life: [cell from chart] x 0.25 x CF (see below)
Example: Micro 100 at 10 hp running 2,000 hrs/yr
Unit Life: 5,000 x 0.25 x 1 = 1,250 hours (or 7.5 months)
CRP 1500
The CRP-1500 is optimized for systems from 125 HP to 600 HP but can be used with systems up to 2,000 HP.
CRP Unit | Width (in) | Depth (in) | Height (in)* | Weight (lbs)** |
---|---|---|---|---|
1500 | 22 | 20 | 57 | 310 |
*Height includes manifold. Height without manifold: 48 in
**shipping weight
HP | ACFM | Lifespan in Hours | Est. Hrs/Yr |
---|---|---|---|
125 | 600 | 30,000 | 8,000 |
150 | 750 | 24,000 | 8,000 |
200 | 1000 | 18,000 | 8,000 |
250 | 1250 | 15,000 | 8,000 |
300 | 1600 | 11,000 | 8,000 |
350 | 1900 | 10,000 | 8,000 |
400 | 2200 | 8,000 | 8,000 |
450 | 2350 | 8,000 | 8,000 |
500 | 2500 | 7,000 | 8,000 |
600 | 3000 | 6,000 | 8,000 |
Lifespan numbers in this chart assume screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Lifespans may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor.
RECIPROCATING COMPRESSORS (8 ppm carryover)
Unit Life: [cell from chart] x 0.25 x CF (see below)
Example: Micro 100 at 10 hp running 2,000 hrs/yr
Unit Life: 5,000 x 0.25 x 1 = 1,250 hours (or 7.5 months)
CRP 2000
The CRP-2000 is optimized for systems from 150 HP to 800 HP but can be used with systems up to 2,000 HP.
CRP Unit | Width (in) | Depth (in) | Height (in) | Weight (lbs)* |
---|---|---|---|---|
2000 | 22 | 20 | 57 | 370 |
*Height includes manifold. Height without manifold: 48 in
**shipping weight
HP | ACFM | Lifespan in Hours | Est. Hrs/Yr |
---|---|---|---|
150 | 750 | 30,000 | 8,000 |
200 | 1000 | 22,000 | 8,000 |
250 | 1250 | 18,000 | 8,000 |
300 | 1600 | 14,000 | 8,000 |
350 | 1900 | 12,000 | 8,000 |
400 | 2200 | 10,000 | 8,000 |
450 | 2350 | 9,000 | 8,000 |
500 | 2500 | 9,000 | 8,000 |
600 | 3000 | 7,000 | 8,000 |
Lifespan numbers in this chart assume screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Lifespans may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor.
RECIPROCATING COMPRESSORS (8 ppm carryover)
Unit Life: [cell from chart] x 0.25 x CF (see below)
Example: CRP-2000 at 800 hp running 2,000 hrs/yr
Unit Life: 6,000 x 0.25 x 1 = 1,500 hours (or 9 months)